KEYPAD (CONTROLS)PWR:Power on (Press in one second) or power off (Press more than 2 seconds when operation).SET:Move to left digit. Short press to toggle CONDɦECɦ!TDS ɦSalt. Long pressing to save setting.CAL:Move to right digit. To clear SD manual record data.MODE:Select sample rate of SD card. Toggle Condɦt1Fɦtds (under K value adjustment mode). Toggle 1413 uS calibration mode to 12.8 mS calibration mode (under Conductivity calibration mode).UNIT:Short pressing to change temperature unit ɗ/ə. Long pressing to select temperature probe type.Short pressing to select NTC: Negative Temperature Coefficient)/ NOT: no remote temperature probe.HOLD:Freeze current readings (Hold shows at top of LCD). Increase value.ADJ: Long press to start SD recording (SD card is inserted to the meter). Decrease value.SET+UNIT: Enter cond. cell constant K value / Temp. coefficient compensation/tds K factor value mode.Long press again to escape the K value setting. Recovery to factory setting (under calibration mode).SET+CAL: Conductivity Calibration.HOLD+PWR: Disable Auto Power Off.OPERATIONCOND/EC/TDS/SALT PROBE INSTALLATION (BNC connector):a) Insert the COND electrode into the top of left hole. And insert the 3.5mm Ø diameter phone jack ATCsensoring parts into the middle of hole.b) Hold the BNC connector in one hand; with the other, insert the braid into the center of the connector.Continuing pushing the braid into the connector until it will not go in any farther. Do this gently and slowly;do not bend the braid.c) Turn the BNC connector in a clockwise direction, until you cannot turn it any more.
FEATURES1)Professional look design accurate portable meters with large LCD display,with BNC connector.2)All electrodes with BNC connector compatible to any other electrodes.3)Hold function, low battery icon indicator, automatic power off in 15 minutesand may be disabled.4)Built-in different temperature compensation selectable:Thermistor 30K, 10K ohm.5)RFS (Recover to FactorySetting) function is included.6)Conductivity calibration points: 1413uS. Calibration solution is included.7)Conductivity electrode may convert to EC, TDS and Salinity concentration, Adjustableconductivity to TDSconversion factor from 0.4 to 1.0. Three in one conductivity electrode(Cond/EC. TDS. Salinity) measurement.8)Conductivity cell constant (K) selectable: 1.0, (Standard) 10 (Optional)(Selectable and adjustable).9)SD card capacity: 1GB to 8GB.10)Tripod receptacle mountable design for long time monitoring purposes.11)All sensors are well calibrated before shipment.12)Warranty period of meter is two years. Electrode is one year.SUPPLIEDzMeterzElectrode x 1pc (Cond./EC/TDS/Salt)zBattery-AAA x 3 pcsz1413uS buffer solution (Cond. K=1) x1 or 12.88mS buffer solution (Cond. K=10)z9V adaptor (optional)zBlack carrying casezOperation manualz8G SD cardADDITIONAL PURCHSEzCDE-11G K=1 electrode replacement (Graphite type)zCDE-11P K=10 option (Platinum type)