This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
HomeAutomobileMotorcycle & PowersportsFluids & MaintenanceTool KitsRemote Wifi Thermostat High Precision Temperature Controller Module Cooling Heating App Temperature Collection Module
Shipped from abroad
915 Generation Remote Wifi Thermostat High Precision Temperature Controller Module Cooling Heating App Temperature Collection Module
₦ 294,882
₦ 560,36447%
3 units left
+ shipping from ₦ 51,854 to LEKKI-AJAH (SANGOTEDO)
0 out of 5
(No ratings available)Promotions
Delivery & Returns
Shipped from abroad
Choose your location
Pickup Station
Delivery Fees ₦ 51,854
Arriving at pickup station between 15 July & 19 July when you order within next 21hrs 15mins
Door Delivery
Delivery Fees ₦ 52,224
Ready for delivery between 15 July & 19 July when you order within next 21hrs 15mins
Return Policy
Free return within 7 days for ALL eligible itemsDetails
Warranty
None
Seller Information
Papating
100%Seller Score
40 Followers
Seller Performance
Order Fulfillment Rate: Excellent
Quality Score: Excellent
Customer Rating: Excellent
Product details
Automatic Mode Function Description: First Select The Heating Mode/Cooling Mode; Set The Temperature And Hysteresis, If You Need To Delay The Start, Then Set The Delay Start Time; If You Need To Set The High And Low Temperature Alarm, Then Set The High And Low Temperature Alarm By Yourself Threshold.Heating Mode Description: When The Detected Temperature (Current Temperature) ≤ Set Temperature - Hysteresis Temperature, The Relay Is Turned On, And The Heating Device Starts To Work;
When The Detected Temperature (Current Temperature) ≥ The Set Temperature, The Relay Is Disconnected, And The Heating Device Stops Working ;Set The Temperature At 30°C, And The Hysteresis Temperature At 5°C;When The Temperature Is 20°C ≤ 25°C (30-5 = 25), The Relay Pulls In And Starts Heating, When The Temperature Reaches 30°C ≥ The Set Temperature 30°C, The Relay Turns Off And Stops Heating;
Delayed Start Function Description: After A Heating/Cooling Process Is Over, How Long Is The Delay (Unit: Second) To Allow The Next Heating/Cooling;Temperature Correction Function: The System Works For A Long Time, And Deviations May Occur. Through This Function Correction, The Current Temperature = Measured Temperature + Calibration Value
Emergency Braking Function (Emergency Stop Function): After The Emergency Stop Is Turned On, The Relay Will Be Disconnected No Matter What State It Is In; After The Emergency Stop Is Turned Off, The Relay Will Return To Normal State;Description Of Cooling ModeWhen The Detected Temperature (Current Temperature) ≥ Set Temperature + Hysteresis Temperature, The Relay Is Turned On, And The Refrigeration Equipment Starts To Work;
When The Detected Temperature (Current Temperature) ≤ Set Temperature, The Relay Is Disconnected And The Refrigeration Equipment Stops Working;Example: Set The Temperature To 30°C, And The Hysteresis Temperature To 5°C;When TheTemperature Is 36°C ≥ 35°C (30+5 = 35), The Relay Pulls In To Start Cooling, And When The Temperature Reaches 30°C ≤ The Set Temperature 30°C, The Relay Turns Off And Stops Cooling;
High And Low Temperature Alarm Function
Buzzer On And Off: After It Is Turned On, The Buzzer Will Sound After An Alarm, And The Buzzer Will Stop Sounding After Pressing The Button;
High Temperature Alarm: After The High Temperature Alarm Is Turned On, The Relay Is Disconnected When The Current Temperature Is Higher Than The High Temperature Alarm Temperature;
Low Temperature Alarm: After The Low Temperature Alarm Is Turned On, The Relay Is Disconnected When The Current Temperature Is Lower Than The Low Temperature Alarm Temperature;
In Automatic Mode, Can The Product Be Disconnected And Run Offline?
In The Automatic Mode, After The Parameters Are Set, The Product Can Run Offline Without The Network, And The Parameters Will Not Be Lost When The Power Is Turned Off.
Lan Data Export Function
A Piece Of Temperature Data Will Be Uploaded To The Lan In 1 Second, And After Clicking "Export", It Will Be Automatically Exported To Excel For Analysis Of The Temperature Data
Colour:black
Material:plastic
Size:6.5 x 3.4cm
Package Contents:
1 x Thermostat Module
Only the above package content, other products are not included.
Note: Light reflection and different displays may cause the color of the item in the picture a little different from the real thing. The measurement allowed error is +/- 1-3cm.
When The Detected Temperature (Current Temperature) ≥ The Set Temperature, The Relay Is Disconnected, And The Heating Device Stops Working ;Set The Temperature At 30°C, And The Hysteresis Temperature At 5°C;When The Temperature Is 20°C ≤ 25°C (30-5 = 25), The Relay Pulls In And Starts Heating, When The Temperature Reaches 30°C ≥ The Set Temperature 30°C, The Relay Turns Off And Stops Heating;
Delayed Start Function Description: After A Heating/Cooling Process Is Over, How Long Is The Delay (Unit: Second) To Allow The Next Heating/Cooling;Temperature Correction Function: The System Works For A Long Time, And Deviations May Occur. Through This Function Correction, The Current Temperature = Measured Temperature + Calibration Value
Emergency Braking Function (Emergency Stop Function): After The Emergency Stop Is Turned On, The Relay Will Be Disconnected No Matter What State It Is In; After The Emergency Stop Is Turned Off, The Relay Will Return To Normal State;Description Of Cooling ModeWhen The Detected Temperature (Current Temperature) ≥ Set Temperature + Hysteresis Temperature, The Relay Is Turned On, And The Refrigeration Equipment Starts To Work;
When The Detected Temperature (Current Temperature) ≤ Set Temperature, The Relay Is Disconnected And The Refrigeration Equipment Stops Working;Example: Set The Temperature To 30°C, And The Hysteresis Temperature To 5°C;When TheTemperature Is 36°C ≥ 35°C (30+5 = 35), The Relay Pulls In To Start Cooling, And When The Temperature Reaches 30°C ≤ The Set Temperature 30°C, The Relay Turns Off And Stops Cooling;
High And Low Temperature Alarm Function
Buzzer On And Off: After It Is Turned On, The Buzzer Will Sound After An Alarm, And The Buzzer Will Stop Sounding After Pressing The Button;
High Temperature Alarm: After The High Temperature Alarm Is Turned On, The Relay Is Disconnected When The Current Temperature Is Higher Than The High Temperature Alarm Temperature;
Low Temperature Alarm: After The Low Temperature Alarm Is Turned On, The Relay Is Disconnected When The Current Temperature Is Lower Than The Low Temperature Alarm Temperature;
In Automatic Mode, Can The Product Be Disconnected And Run Offline?
In The Automatic Mode, After The Parameters Are Set, The Product Can Run Offline Without The Network, And The Parameters Will Not Be Lost When The Power Is Turned Off.
Lan Data Export Function
A Piece Of Temperature Data Will Be Uploaded To The Lan In 1 Second, And After Clicking "Export", It Will Be Automatically Exported To Excel For Analysis Of The Temperature Data
Colour:black
Material:plastic
Size:6.5 x 3.4cm
Package Contents:
1 x Thermostat Module
Only the above package content, other products are not included.
Note: Light reflection and different displays may cause the color of the item in the picture a little different from the real thing. The measurement allowed error is +/- 1-3cm.
Specifications
Key Features
- Durable and good quality
- Thermostat Module
- High Precision Module
- Temperature Controller Module
- Temperature Controller
- Controller Module
- The details are as described above
What’s in the box
1 x Thermostat Module
Specifications
- SKU: 91368OP3B4ZE3NAFAMZ
- Production Country: China
- Size (L x W x H cm): 12x5x3
- Weight (kg): 0.03
- Color: multicolor
Verified Customer Feedback
Customers who have bought this product have not yet posted comments
915 Generation Remote Wifi Thermostat High Precision Temperature Controller Module Cooling Heating App Temperature Collection Module
₦ 294,882
₦ 560,36447%
Questions about this product?